Temperature Control Panels
We design and build temperature control panels for industrial processes: from a simple panel with a controller and a contactor, to systems with proportional SCR control and two layers of over-temperature protection.
- Type J, K thermocouples and more Sensor input
- PID with auto-tuning Algorithm
- Independent high limit Protection
- NEMA 1 · 4/4X · 12 Enclosure
- Direct manufacturer
- ISO 9001:2015
- Reply in under 2 h
Who builds these control panels
Assembled here, not resold
Omega Heaters de México has spent over 25 years building industrial electric heating elements, and its control panels are assembled at its plant in Guadalupe, Nuevo León, Mexico. Direct manufacturer: you quote with the people who build your panel.
- Direct manufacturer Our own plant in Guadalupe, Nuevo León, Mexico. We are not distributors.
- Over 25 years Building industrial electric heating elements for industry across northern Mexico.
- ISO 9001:2015 Certified processes and raw materials, audited, with a warranty against manufacturing defects.
- Wiring diagram included For your records and for whoever services it later. We do not hand over closed boxes with no drawing.
- Built to NOM-001-SEDE Protection, wire gauges and grounding to the Mexican electrical code, not by guesswork.
- Enclosure to suit your environment NEMA 1, NEMA 4/4X for washdown or outdoors, and NEMA 12 for dust.
- Heater from the same supplier Panel, thermocouple and heater come out of the same plant, so the loop arrives complete and nobody passes the blame.
Technical data
Specifications
- Sensor input
- Type J, K or other thermocouples, universal input
- Control mode
- On/Off with contactor, or proportional with SCR
- Algorithm
- PID with auto-tuning
- Control output
- Electromechanical relay, SSR or analog
- Temperature protection
- Independent high-limit controller, always recommended
- Enclosure rating
- NEMA 1 · NEMA 4/4X for washdown or outdoors · NEMA 12 for dust
- Instrument
- Standard DIN sizes, interchangeable
- Code compliance
- Protection, wire gauges and grounding per NOM-001-SEDE, the Mexican electrical code
- Delivered with
- Wiring diagram included for your records
Aplicaciones
- Control of tubular, band, cartridge and open coil heaters.
- Industrial furnaces and heat treatment chambers.
- Plastic injection and extrusion processes, across multiple zones.
- Immersion tanks and industrial bain-maries.
- HVAC systems with electric duct heaters.
Qué ganas
- Precise control: the digital controllers work to industrial accuracy, with a self-tuning PID algorithm.
- Two layers of safety when a process controller is specified together with an independent over-temperature controller.
- Less commissioning time: the panel arrives fully wired, tested and ready to connect to supply, load and sensor.
- An enclosure chosen for the real conditions in your plant, which avoids failures from corrosion, dust or moisture.
EMERGENCY SUPPORT
Panel no longer holding temperature? Send a photo on WhatsApp.
No drawing and no diagram needed. From a photo of the inside of the panel and the kW of your heaters, an engineer will tell you right away whether it can be repaired or should be replaced, whether a contactor or an SCR suits you better, and how long it takes to build.
1
Tell us your process and your load
what you are heating, how many kW or amps, and what thermocouple type you use, or whether you want us to recommend one.
2
Tell us where it will be installed
indoors, outdoors, a washdown area, or where there is dust or chemicals.
3
Te recomendamos la configuración
contactor or SCR, enclosure type, and whether you need over-temperature protection.
Te contesta un ingeniero de aplicaciones
Lun–Vie 9:00–17:00 · respuesta < 2 h
Frequently asked questions
What we get asked most
What is the difference between a contactor panel and an SCR panel?
A contactor switches the heater fully on and off; it costs less but wears mechanically with frequent cycling. An SCR regulates power proportionally, with no moving parts, and gives finer control — recommended if your process needs high precision or cycles very often.
Do I need over-temperature protection on top of the main controller?
It is recommended on any process where overheating could damage the product or the equipment, or create a hazard. An independent over-temperature controller cuts power even if the main controller fails, so that instrument is not the system's single point of failure.
Which enclosure do I need for my plant?
It depends on the environment: NEMA 1 for a clean, dry indoor area, NEMA 4/4X where there is pressure washing, outdoor exposure or corrosive atmospheres, and NEMA 12 where there is dust. Tell us where the panel will be installed and we will recommend the right rating.
Which thermocouple type does the panel work with?
Our controllers have a universal input, compatible with type J, K and others. If you have not settled on a type, tell us your process temperature range and we will help you choose — see Type J Thermocouple Wire and Type K Thermocouple Wire.
What is the lead time?
3 to 5 business days for standard contactor panels. Designs with SCR, multiple control zones or special enclosures take longer — ask about availability over WhatsApp.
What else is a temperature control panel called?
It also goes by control cabinet, temperature controller panel, pyrometer panel and heater control panel. It is the assembled, wired cabinet that controls and protects your heaters.
Which controller brands do you build with?
We work with the brands that can be bought and serviced in Mexico — Autonics, Novus, Watlow, Honeywell, Delta, Full Gauge and equivalents — and we build with whichever one you already run in your plant, so your people do not have to learn another instrument and you have local spares. If you have no preference, we will recommend one and tell you why.
How many kW can the panel handle?
We build it to your load, from a single-zone panel with a controller and a contactor up to multi-zone systems with proportional SCR control. Tell us the kW and the voltage of your heaters, how many zones there are and what thermocouple type you use, and from that we size contactors, SCRs, protection devices and wire gauge.
I don't have a diagram. How do I get a quote?
Send us a photo of the inside of the panel and another of the data plate on your heaters. With that we will tell you whether it can be repaired or should be replaced, and which makes more sense. We build in Guadalupe, Nuevo León, and we also visit plants in the Monterrey area.
CATÁLOGO • MÁS MODELOS
¿Buscas otra configuración?
Browse other control panel models and control accessories.
Ver todos los modelos
Quote on WhatsApp